verticalcompare
Brand
Model
Other models
Electricity costs
(€ in 8 years)
Total display area (m2)
Net volume (liters)
Storage temperature (°C)
Temperature class
Climate class
Draft energy index
Energy (kWh/year)
Refrigerant
Cooling
Countries available
05/03/2018
AHT AHT AHT ArcaBoa AHT AHT AHT AHT AHT AHT AHT Novum Liebherr Novum Liebherr Liebherr Liebherr Liebherr Carrier AHT Liebherr Novum ArcaBoa ArcaBoa Novum ArcaBoa Inefficient model
Macao 210 (U) ... Athen XL ECO 175 (-) ... Paris ECO 185 (U) ... Dupla Topo DR Sydney XL 213 (-) ... Athen XL ECO 250 (U) ... Miami ECO 185 (U) L ... Ibiza 210 (U) ... Ibiza 145 (U) ... Macao 145 (U) ... Manhattan ECO 175 (U) ... Aran 806 SC STs 1072 Line 601FF (no lighting) STm 972 STEs 772 STs 872 STm 1172 Multinor 1530 G Paris ECO 250 (U) ... STEm 872 Grand Cayman 1008 SC (no lighting) Super 2 DR Super 2.5 DR 601L (no lighting) Dupla 2.2 DR  
Macao 210 (-) ...   Paris ECO ... : 185 (-), 180 (U), 180 (-), 175 (U), 175 (-), 145 (U), 145 (-) Dupla Topo R Sydney XL ... : 213 (U), 223 (U), 223 (-), 230 (-), 250 (U), 175 XL (U), 175 XL (-), 210 XL (U), 210 XL (-), 250 XL (U), 250 XL (-) Athen XL ECO... : 250 (-), 210 (U), 210 (-), 207 (U), 207 (-) Miami ECO ...: 185 (-), 210 (U), 210 (-), 250 (U) L, 250 (-) Ibiza 210 (-) ... Ibiza 145 (-) ... Macao 145 (-) ... Manhattan ECO 175 (-) ...   SGTs 1072 Line 601FFL, Line 610FF (no lighting), Line 610FFL SGTm 972 SGTEs 772 SGTs 872 SGTm 1172   Paris ECO ... : 250 (-), 210 (U), 210 (-) SGTEm 872 Grand Cayman 1008 SC-LED, Grand Cayman 1008 EOA (no lighting), Grand Cayman 1008 EOA-LED Super 2 R Super 2.5 R 610L (no lighting), 601L (with LED), 610L (with LED) Dupla 2.2 R  
3797 3797 3182 2294 3738 5203 4038 4789 3680 3387 4016 4594 2712 2453 2627 2366 2594 2851 1928 3766 2398 3504 3504 4205 1862 5549 6717
1.26 1.25 1.04 0.65 1.39 1.86 1.26 1.3 0.86 0.84 1.08 1.14 1.68 0.8 1.4 1.19 1.4 1.68 1.03 1.54 1.19 1.48 1.49 1.9 0.82 2.65 1.56
338 709 529 334 677 1025 547 561 342 217 605 742 740 468 664 497 601 816 242 770 550 830 580 750 484 1255 893
–18...–23/ 0...+2/ +3...+15 –18...–23 –18...–23/ 0...+2/ +3...+15 –18...–23 –18...–23 –18...–23/ 0...+2/ +3...+15 -18...-23 –18...–23/ 0...+2/ +3...+15 –18...–23/ 0...+2/ +3...+15 –18...–23/ 0...+2/ +3...+15 –18...–23/ 0...+2/ +3...+15 –18...–25 –18...–23 –18...–23 –18...–23 –18...–23 –18...–23 –18...–23 –18...–23 –18...–23/ 0...+2/ +3...+15 –18...–23 –18...–23 –18...–23 –18...–23 –18...–23 –18...–23 -18...-25
L1 (-15...-18°C) L1 (-15...-18°C) L1 (-15...-18°C)/S/S L1 (-15...-18°C) L1 (-15...-18°C) L1 (-15...-18°C) L1 (-15...-18°C) L1 (-15...-18°C) L1 (-15...-18°C) L1 (-15...-18°C) L2 (-12...-18°C) L1 (-15...-18°C) L1 (-15...-18°C) L1 (-15...-18°C) L1 (-15...-18°C) L1 (-15...-18°C) L1 (-15...-18°C) L1 (-15...-18°C) 3H L1 (-15...-18°C)/S/S L1 (-15...-18°C) L1 (-15...-18°C) L1 (-15...-18°C) L1 (-15...-18°C) L1 (-15...-18°C) L1 (-15...-18°C) L1 (-15...-18°C)
3 (25°C, 60% RH) 3 (25°C, 60% RH) 3 (25°C, 60% RH) 3 (25°C, 60% RH) 3 (25°C, 60% RH) 3 (25°C, 60% RH) 3 (25°C, 60% RH) 3 (25°C, 60% RH) 3 (25°C, 60% RH) 3 (25°C, 60% RH) 3 (25°C, 60% RH) 3 (25°C, 60% RH) 3 (25°C, 60% RH) 3 (25°C, 60% RH) 3 (25°C, 60% RH) 3 (25°C, 60% RH) 3 (25°C, 60% RH) 3 (25°C, 60% RH) 3 (25°C, 60% RH) 3 (25°C, 60% RH) 3 (25°C, 60% RH) 3 (25°C, 60% RH) 3 (25°C, 60% RH) 3 (25°C, 60% RH) 3 (25°C, 60% RH) 3 (25°C, 60% RH) 3 (25°C, 60% RH)
39.3 39.5 37.9 37.2 35.9 39.7 41.8 48.4 49.9 46.7 46.5 44.7 22.5 34.9 25.1 25.6 24.8 23.6 23.1 33.4 25.9 32.1 31.9 31.6 26.1 31.4 59.0
2'373 2'373 1'989 1'434 2'336 3'252 2'524 2'993 2'300 2'117 2'510 2'871 1'695 1'533 1'642 1'479 1'621 1'782 1'205 2'354 1'499 2'190 2'190 2'628 1'164 3'468 4'198
R290 R290 R290 R290 R290 R290 R290 R290 R290 R290 R290 R290 R290 R290 R290 R290 R290 R290 R290 R290 R290 R290 R290 R290 R290 R290 R507
Static/ Forced-air/ Forced-air Static Static/ Forced-air/ Forced-air Static Static Static/ Forced-air/ Forced-air Static/ Forced-air/ Forced-air Static/ Forced-air/ Forced-air Static/ Forced-air/ Forced-air Static/ Forced-air/ Forced-air Static/ Forced-air/ Forced-air Forced-air Static Forced-air Static Static Static Static Forced-air Static/ Forced-air/ Forced-air Static Forced-air Static Static Static Static Static
EU EU EU EU EU EU EU EU EU EU EU EU EU EU EU EU EU EU EU EU EU EU EU EU EU EU EU