verticalcompare
Brand
Model
Other models
Electricity costs
(€ in 8 years)
Net volume (liters)
Storage temperature (°C)
Climate class
Energy efficiency class
Energy Efficiency Index
Energy (kWh/year)
Refrigerant
Cooling
Dimensions W/D/H (mm)
Countries available
20/02/2019
Liebherr Adande Inefficient model Gram Adande Adande Liebherr
GGU 1500 VCC R2   COMPACT F 210 LG VLS R2 VCS R2 Side Engine GGU 1400
GGU 1550     COMPACT F 210 RG   VCR R2 Rear Engine, VCM R2  
730 1525 1867 1448 1250 1218 933
107 68.8 100 76 64.8 86.2 101
-26...-9 -22...+15 -22...-5 -22...-5 -22...+15 -22...+15 -32...-15
4 4 4 4 5 - heavy-duty 5 - heavy-duty  
(A) B C B B B (A)
15.2 34.2 39.4 32 28.3 26.4 19.6
456 953 1'167 905 781 761 583
R600a R600a R134a R600a R600a R600a R600a
Static Forced-air Forced-air Forced-air Forced-air Forced-air Static
600 x 615 x 830 450 x 800 x 845 600 x 600 x 830 595 x 640 x 830 1100 x 700 x 436 1100 x 700 x 494 600 x 615 x 830
AT, BG, CH, DE EU EU EU EU EU EU ∖ AT